Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

CNW 806

Three-phase-dv/dt filter

CNW 806

Unique Selling Point


  • Protection for electrical consumers
  • Limitation of the voltage rise on <500V / us
  • Extended service life of electrical consumers
  • Low leakage currents on the motor
  • Reduced losses
  • Easy construction
  • Compact design
  • Production according to UL insulation system E251513 possible

Description


Reduce voltage rice to < 500V/µs - electrical consumrs and insulation will protected with low costs. 

A simple and inexpensive method for reducing the rate of voltage rise is to use a du / dt filter or throttle. It dampens the voltage rise to acceptable values and prevents overvoltages on long supply lines.

Losses and heating are minimized and the leakage current reduced. By limiting the rate of voltage rise, the motor insulation is protected and thus prolongs the life.

Also, the electromagnetic interference can be reduced in the radiation range of 1 MHz to 30 MHz.

  • Rated voltage: U ≤ 3 x 500 V
  • Reduce voltage rice to < 500V/µs
  • Field frequency: 0 - 60 Hz
  • Drive switching frequency: up to 150 A >4kHz, from 150 A >1,5KHz
  • According to: EN 60289 / EN 61558
  • Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s
  • Insulation class: T40/F
  • Protection rating: IP00
  • Climatic categorie: DIN IEC 60068-1
  • Overload: 1,5 x INenn 1 min / h
  • Ambient temperature: 40 °C
  • Design: standing on foot angle


Typical applications

  • Drive systems for motor drives:
    • Mechanical engineering
    • Elevators / escalators
    • Pipes
    • Conveyor technology
    • Ventilation and air conditioning
    • Robotics
    • Automation technology
  • Power supplies
  • Wind turbines


Technical Data


  • Nominal Voltage : 500 V
  • Rated current : 4 - 1200 A
  • Inductance : 0,005 - 1,5 mH

Circuit example

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 806

Three-phase-dv/dt filter

Technical data

Type

Rated voltage
[V]

Ragted current
[A]

Inductance
[mH]

Resistance
[mΩ]

Power loss
[W]

Uk @ 400 V

[%]

Uk @ 230 V

[%]

Uk @ 480 V

[%]

Uk @ 500 V

[%]

CNW 806/4

400 - 500 V

4

1,5

37,0

7

0,8

1,4

0,7

0,7

CNW 806/10

10

0,6

13,8

13

1,4

0,7

0,7

CNW 806/18

18

0,33

5,8

17

1,4

0,7

0,7

CNW 806/24

24

0,245

4,7

22

1,4

0,7

0,6

CNW 806/37

37

0,16

2,7

29

1,4

0,7

0,6

CNW 806/48

48

0,123

1,8

33

1,4

0,7

0,6

CNW 806/65

65

0,09

0,65

37

1,4

0,7

0,6

CNW 806/90

90

0,065

0,4

46

1,4

0,7

0,6

CNW 806/120

120

0,05

0,45

60

1,4

0,7

0,7

CNW 806/150

150

0,039

0,35

80

1,4

0,7

0,6

CNW 806/180

180

0,033

0,35

100

1,4

0,7

0,7

CNW 806/200

200

0,029

0,29

100

1,4

0,7

0,6

CNW 806/250

250

0,024

0,22

130

1,4

0,7

0,7

CNW 806/300

300

0,02

0,15

130

1,4

0,7

0,7

CNW 806/350

350

0,017

0,12

130

1,4

0,7

0,7

CNW 806/400

400

0,015

0,1

150

1,4

0,7

0,7

CNW 806/500

500

0,012

0,1

200

1,4

0,7

0,7

CNW 806/600

600

0,010

0,08

250

1,4

0,7

0,7

CNW 806/700

700

0,008

0,07

260

1,3

0,6

0,6

CNW 806/800

800

0,007

0,06

280

1,3

0,6

0,6

CNW 806/900

900

0,0065

0,05

300

1,4

0,7

0,6

CNW 806/1000

1000

0,006

0,05

360

1,4

0,7

0,7

CNW 806/1200

1200

0,005

0,05

480

1,4

0,7

0,7

 

Dimension drawings

Image 1
Image 2
 
Your contact: +49 - 212 8804-0 • info@reo.de

CNW 806

Three-phase-dv/dt filter

Dimension drawings

Image 3

 

Dimensions

Type

L
[mm]

B
[mm]

H
[mm]

N1
[mm]

N2

[mm]

D

[mm]

Aluminium
[kg]

Copper
[kg]

Weight
[kg]

Connecton

Image

CNW 806/4

95

47

106

56

34

4.8 x 9.0

0

0,4

1,1

2.5 mm²

1

CNW 806/10

95

56

106

56

43

4.8 x 9.0

0

0,5

1,5

2.5 mm²

1

CNW 806/18

125

60

160

100

45

5 x 8

0

0,9

2,2

2.5 mm²

2

CNW 806/24

125

60

160

100

45

5 x 8

0

1,0

2,3

4 mm²

2

CNW 806/37

125

70

160

100

55

5 x 8

0

1,1

2,8

6 mm²

2

CNW 806/48

155

77

187

130

57

8 x 12

0

1,6

4

10 mm²

2

CNW 806/65

155

91

187

130

71

8 x 12

0

2,1

6

10 mm²

2

CNW 806/90

190

110

157

170

67

8 x 12

0

3,0

9

25 x 3

3

CNW 806/120

230

108

200

176

71

9 x 13

0,9

0,7

10

25 x 3

3

CNW 806/150

240

115

209

185

74

10 x 18

0,8

0,9

11

30 x 3

3

CNW 806/180

240

125

210

185

84

10 x 18

0,7

0,8

13

30 x 3

3

CNW 806/200

240

128

210

185

84

10 x 18

0,9

1,0

14

30 x 4

3

CNW 806/250

300

121

262

224

78

10 x 18

1,1

1,3

16

30 x 4

3

CNW 806/300

300

124

262

224

78

10 x 18

1,7

1,3

16

30 x 4

3

CNW 806/350

300

136

263

224

78

10 x 18

2,4

2,2

18

40 x 5

3

CNW 806/400

300

151

263

224

95

10 x 18

2,2

2,2

24

40 x 5

3

CNW 806/500

300

159

294

224

95

10 x 18

3,3

2,6

27

40 x 5

3

CNW 806/600

300

177

293

224

105

10 x 18

2,5

4,4

32

40 x 8

3

CNW 806/700

300

177

325

224

105

10 x 18

3

4,9

35

40 x 8

3

CNW 806/800

300

194

325

224

105

10 x 18

3,8

5,2

36

40 x 8

3

CNW 806/900

420

207

387

316

124

13 x 20

5,5

10,7

55

60 x 10

3

CNW 806/1000

420

217

388

316

124

13 x 20

5,9

10,8

56

60 x 10

3

CNW 806/1200

420

217

389

316

124

13 x 20

6

10,8

56

60 x 10

3