Unique Selling Point


  • No saturation
  • Wide range of material selection 
  • Special protective coating 
  • High linearity L (i) 
  • Very good mechanical strength 
  • No hysteresis 
  • Optimal weight by forced air cooling 
  • Directional air flow through GRP conduits
  • Very efficient liquid cooling option (waveguide) 
  • Able to be universally applied.

Description


Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.

With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.

  • Frequency of the current: DC und AC
  • Tolerances: + 10 / - 10 %, + 5 / - 5 %
  • Taps: By default, no taps (available on request)
  • Insulation: F or H
  • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF
  • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs
  • Mounting: Suspended, vertical or horizontal
  • Mechanical strength, mechanical simulation (FEM): EN 12663
  • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B

REO Mix & Match principle 

With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.

REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.

Optional

  • Layer winding/Disc winding
  • Aluminium, Copper or aluminium+copper
  • Protections: Paint coating, protective coating, housing or REO Xtreme
  • Cooling fan/unit
  • Sensors: Switch NO / NC, PT100, NTC, PTC


Technical Data


  • Rated current : 50 - 1000 A
  • Inductance : 0,2 - 8 mH

Circuit example

Your contact: +49 - 212 8804-0 • info@reo.de

LD 100

Air choke with copper/layer winding

Technical data

Type

Inductance 
[mH]

Cooling 3 m/s

Cooling 5 m/s

Cooling 8 m/s

I
[A]

magn. Energy
[J]

P [kVA]
at 20°C

I
[A]

magn. Energy
 [J]

P [kVA]
at 20°C

I
[A]

magn. Energy
 [J]

P [kVA]
at 20°C

LD 100/50/0,2

0,2

50

0,25

0,1

60

0,4

0,1

70

0,5

0,2

LD 100/100/0,2

0,2

100

1

0,2

120

1,4

0,2

145

2,1

0,4

LD 100/200/0,2

0,2

200

4

0,4

240

5,8

0,6

280

7,8

0,8

LD 100/400/0,2

0,2

400

16

0,9

490

24

1,4

585

34,2

1,9

LD 100/700/0,2

0,2

700

49

1,6

850

72,3

2,3

1020

104

3,3

LD 100/1000/0,2

0,2

1000

100

1,7

1225

150,1

2,6

1450

210,3

3,7

LD 100/50/0,5

0,5

50

0,625

0,2

60

0,9

0,2

72

1,3

0,3

LD 100/100/0,5

0,5

100

2,5

0,3

122

3,7

0,4

145

5,3

0,6

LD 100/200/0,5

0,5

200

10

0,6

245

15

0,9

295

21,8

1,3

LD 100/400/0,5

0,5

400

40

1,5

490

60

2,2

585

85,6

3,1

LD 100/700/0,5

0,5

700

122,5

2,7

865

187,1

4,1

1030

265,2

5,7

LD 100/1000/0,5

0,5

1000

250

3,1

1200

360

4,5

1430

511,2

6,4

LD 100/50/1

1

50

1,25

0,2

60

1,8

0,3

72

2,6

0,5

LD 100/100/1

1

100

5

0,5

125

7,8

0,8

147

10,8

1,1

LD 100/200/1

1

200

20

0,9

240

28,8

1,4

290

42,1

2

LD 100/400/1

1

400

80

2,2

490

120,1

3,3

585

171,1

4,7

LD 100/700/1

1

700

245

4,1

870

378,5

6,4

1030

530,5

8,9

LD 100/1000/1

1

1000

500

5

1200

720

7,1

1430

1022,5

10,1

LD 100/50/2

2

50

2,5

0,4

63

4

0,6

75

5,6

0,8

LD 100/100/2

2

100

10

0,9

125

15,6

0,8

147

21,6

1,1

LD 100/200/2

2

200

40

1,4

245

60

2,2

290

84,1

3

LD 100/400/2

2

400

160

3,6

490

240,1

5,3

580

336,4

7,5

LD 100/700/2

2

700

490

6,5

870

756,9

10

1030

1060,9

14,1

LD 100/1000/2

2

1000

1000

7,2

1250

1562,5

11,2

1480

2190,4

15,8

LD 100/50/4

4

50

5

0,6

63

7,9

0,9

75

11,3

1,3

LD 100/100/4

4

100

20

1,3

123

30,3

1,9

145

42,1

2,7

LD 100/200/4

4

200

80

2,2

245

120,1

3,3

290

168,2

4,6

LD 100/400/4

4

400

320

5,6

490

480,2

8,5

580

672,8

11,9

LD 100/700/4

4

700

980

9,9

870

1513,8

15,2

1040

2163,2

21,8

LD 100/1000/4

4

1000

2000

11

1250

3125

17,8

1480

4380,8

24,9

LD 100/50/8

8

50

10

11,4

64

16,4

1,4

77

23,7

2

LD 100/100/8

8

100

40

1,9

125

62,5

3

150

90

4,4

LD 100/200/8

8

200

160

3,4

245

240,1

5

290

336,4

7,1

LD 100/400/8

8

400

640

8,5

490

960,4

12,7

585

1368,9

18,2

LD 100/700/8

8

700

1960

15,3

875

3062,5

23,9

1050

4410

34,4

Your contact: +49 - 212 8804-0 • info@reo.de

LD 100

Air choke with copper/layer winding

Dimension drawings

Air choke with layer winding (without cooling unit)

Air choke with disc winding (without cooling unit)

 


Air choke with layer winding (with cooling unit 0,3m³/s)

 


Air choke with layer winding (with cooling unit 0,6m³/s)

 

 

 

Your contact: +49 - 212 8804-0 • info@reo.de

LD 100

Air choke with copper/layer winding

Dimensions

Type


[mm]


[mm]


[mm]

Copper
[kg]

Weight
[kg]

Type


[mm]


[mm]


[mm]

Copper
[kg]

Weight
[kg]

LD 100/50/0,2

150

150

60

1,5

5

LD 100/50/2

250

250

80

5,1

9

LD 100/100/0,2

180

180

80

3,6

7

LD 100/100/2

250

250

120

11,7

16

LD 100/200/0,2

220

220

130

8,5

13

LD 100/200/2

400

400

150

35,9

45

LD 100/400/0,2

350

350

170

19,7

27

LD 100/400/2

420

420

280

88,9

102

LD 100/700/0,2

350

350

270

51,3

62

LD 100/700/2

450

450

480

212

234

LD 100/1000/0,2

400

400

340

110

123

LD 100/1000/2

550

550

580

460

495

LD 100/50/0,5

180

180

60

2,2

6

LD 100/50/4

250

250

100

7,8

12

LD 100/100/0,5

200

200

90

6,2

10

LD 100/100/4

300

300

130

17,4

23

LD 100/200/0,5

300

300

140

16,7

23

LD 100/200/4

400

400

200

55,1

68

LD 100/400/0,5

400

400

170

36,5

45

LD 100/400/4

450

450

410

141

157

LD 100/700/0,5

400

400

270

86,4

98

LD 100/700/4

550

550

550

321

354

LD 100/1000/0,5

500

500

310

173

188

LD 100/1000/4

550

550

770

727

770

LD 100/50/1

180

180

70

3,3

7

LD 100/50/8

250

250

120

11,8

16

LD 100/100/1

250

250

110

8,6

12

LD 100/100/8

350

350

140

26,9

36

LD 100/200/1

350

350

140

23,5

31

LD 100/200/8

450

450

240

83,9

98

LD 100/400/1

420

420

190

55

66

LD 100/400/8

500

500

470

212

231

LD 100/700/1

420

420

360

134,3

148

LD 100/700/8

550

550

750

499

545

LD 100/1000/1

550

550

400

266

283