Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

CNW M 905

Fully encapsulated three-phase mains choke 2% Uk

CNW M 905

Unique Selling Point


  • Usable in rough environment
  • Protection ratings: IP00 - IP66 
  • Optimal mechanical protection of the choke
  • Extended life-time of electrical consumers
  • Attenuation of current spikes of up to 60%
  • Reduction of the input current up to 20%
  • Assembly of different options: cables, terminals, terminal box
  • Lower surface temperature 
  • Low noise 
  • Manufaturing according to UL insulation system E251513 possible

Description


The mains chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.

Power Noise Reduction - save up to 15% energy costs. A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.

Starting currents and current peaks are reduced up to 30%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.

  • Rated voltage: U ≤ 3 x 500 V
  • Short circuit: Uk 2% (400VAC/50Hz, INenn)
  • Frequency:  50/60 Hz
  • According to: EN 60289 / EN 61558
  • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min
  • Insulation class: T40/F
  • Protection rating: IP00 up to IP66
  • Climatic categorie: DIN IEC 60068-1
  • Overload: 1,5 x INenn 1 min / h
  • Design: mounted on footprint

 

Typical applications

  • Drive systems for motor drives:
    • Mechanical engineering
    • Elevators / escalators
    • Pipes
    • Conveyor technology
    • Ventilation and air conditioning
    • Robotics
    • Automation technology
  • Power supplies
  • Wind turbines

 

Technical Data


  • Nominal Voltage : 500 V
  • Rated current : 3 - 36 A
  • Inductance : 0,4 - 4,8 mH

 

Circuit example

Your contact: +49 - 212 8804-0 • info@reo.de

CNW M 905

Fully encapsulated three-phase mains choke 2% Uk

Technical data

Type

Rated voltage/ Rated frequency
[V]

Rated current
[A]

Rated inductance per line
[mH]

Copper
[kg]

Weight
[kg]

Strand
[mm²]

CNW M 905/3

Up to 3 x 500V

3

4,8

0,4

1,2

1,5

CNW M 905/6

6

2,4

0,4

1,2

1,5

CNW M 905/8

8

1,8

0,5

1,9

1,5

CNW M 905/10

10

1,4

0,5

1,9

1,5

CNW M 905/12

12

1,2

0,9

2,7

1,5

CNW M 905/16

16

0,91

0,9

2,7

2,5

CNW M 905/25

25

0,58

1,0

3,7

4,0

CNW M 905/36

36

0,40

1,0

3,7

6,0

Higher power ratings on request

 

For Europe

For USA

Frequency: 50 Hz

Frequency: 60 Hz

Short circuit voltage Uk: 4% (by 400V)

Short circuit voltage Uk: 9,6% (by 200V)

Voltage drop: 9,23 V/branch

Voltage drop: 11,05 V/branch

Your contact: +49 - 212 8804-0 • info@reo.de

CNW M 905

Fully encapsulated three-phase mains choke 2% Uk

 

Dimension drawings

 

Dimensions

Type

Image

L1

[mm]

L2

[mm]

B

[mm]

H1
[mm]

H2
[mm]

N1
[mm]

N2

[mm]

ØD
[mm]

A1
[mm]

CNW M 905/3

1

2

3

115

155

115

100

115

-

65

47

47

88

88

97,5

-

-

91

80

140

-

51

26

-

5,5x7,0

5,5x7,0

-

200

200

200

CNW M 905/6

1

2

3

115

155

115

100

115

-

65

47

47

88

88

97,5

-

-

91

80

140

-

51

26

-

5,5x7,0

5,5x7,0

-

200

200

200

CNW M 905/8

1

2

3

115

155

115

100

115

-

74

56

56

88

88

97,5

-

-

91

80

140

-

60

35

-

5,5x7,0

5,5x7,0

-

200

200

200

CNW M 905/10

1

2

3

115

155

115

100

115

-

74

56

56

88

88

97,5

-

-

91

80

140

-

60

35

-

5,5x7,0

5,5x7,0

-

200

200

200

CNW M 905/12

1

2

3

140

180

140

125

140

-

77

51

51

113

113

122,5

-

-

116

100

165

-

60

30

-

5,5x7,0

5,5x7,0

-

200

200

200

CNW M 905/16

1

2

3

140

180

140

125

140

-

77

51

51

113

113

122,5

-

-

116

100

165

-

60

30

-

5,5x7,0

5,5x7,0

-

200

200

300

CNW M 905/25

1

2

3

140

180

140

125

140

-

87

61

61

113

113

122,5

-

-

116

100

165

-

70

40

-

5,5x7,0

5,5x7,0

-

200

200

300

CNW M 905/36

1

2

3

140

180

140

125

140

-

87

61

61

113

113

122,5

-

-

116

100

165

-

70

40

-

5,5x7,0

5,5x7,0

-

200

200

300

Your contact: +49 - 212 8804-0 • info@reo.de

CNW M 905

Fully encapsulated three-phase mains choke 2% Uk

Dimension drawings of options

Dimensions of options

Type

IP 20

IP 20 + EMV

IP 64/66

 

Terminals

Terminals

+ EMC - strain relief

Terminal box with EMC-screw connection

 

Cross section

[mm2]

H1

[mm]

H1

[mm]

L1
[mm]

Screw connection

L1
[mm]

B1

[mm]

H1
[mm]

CNW M 905/3

2,5

35

34

130

M 20

151

85

60

CNW M 905/6

2,5

35

34

130

M 20

151

85

60

CNW M 905/8

2,5

35

34

130

M 20

151

85

60

CNW M 905/10

2,5

35

34

130

M 20

151

85

60

CNW M 905/12

2,5

35

34

160

M 20

151

85

60

CNW M 905/16

2,5

35

34

160

M 20

151

85

60

CNW M 905/25

6,0

35

34

160

M 25

155

85

60

CNW M 905/36

6,0

35

34

160

M 32

210

120

80

Your contact: +49 - 212 8804-0 • info@reo.de

CNW M 905

Fully encapsulated three-phase mains choke 2% Uk

 

Installation

 

 

 

  

Assembly

for terminal connection in IP 64/66 enclosure with PE-screw connection for M4 and laterally assembled capacitor block (enclosed)

 

 

 

 Assembly

for terminal connection with screen in IP 20 design with PE-screw connection for M4 and laterally assembled capacitor block

 

Assembly

for terminal connection in IP 20 design with PE-screw connection for M4 and laterally assembled capacitor block

 

 

 

 

 

Assembly 

with cables with PE-plug-in connection 6,3 x 0,8 and laterally assembled capacitor block