Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

REOLAB 320

REO three-phase AC - High voltage supply galvanically isolated from mains

REOLAB 320

Unique Selling Point


  •     Clean sine wave voltage at the output over the entire output range
  •     Does not produce EMC interference
  •     Voltage presetting in manual or control mode possible
  •     The output voltage is kept constant at ± 1.5% by means of a controller
  •     The switch-on and switch-off times of the desired output voltage can be set via a built-in timer
  •     Fast compensation in case of voltage fluctuations
  •     True RMS measurement by means of digital measuring devices
  •     External operation via Profibus possible

Description


Applications:

For endurance tests up to 5 kV, the high-voltage supply with galvanic isolation provides the entire power supply for test fields of quality assurance.

Equipment:

  •     Circuit breaker with magnetic and thermal tripping in the mains input
  •     Main contactor for switching the transformers in operation
  •     Emergency stop button and safety loop with warning lamps
  •     Timer for the main contactor
  •     Pushbuttons and indicators
  •     10-speed setpoint potentiometer for voltage adjustment
  •     Protection against short-circuit and overload of the output
  •     Digital measuring instruments V + A 96 x 48 mm in AC output
  •     Electronic control of all three phases for voltage stabilization
  •     Mobile electronic housing

Technical Data


Options

  •     PLC with Powerformer
  •     Coupling module with REODATA
  •     Interface DP 59211 with Profibu
Your contact: +49 - 212 8804-0 • info@reo.de

REOLAB 320

REO three-phase AC - High voltage supply galvanically isolated from mains

Typ

Nominal voltage
[V]

Nominal power

[kVA]

Output voltage

[V]

Output current

[A]

Gear shift

REOLAB 320/1,3

 

0-1,3

3 x 0-3000

 

star/star

REOLAB 320/1,73

3 x 400

0-1,73

3 x 0-4000

3 x 0,25

star/star

REOLAB 320/2,16

50 / 60 Hz

0-2,16

3 x 0-5000

 

 

Control accuracy: ± 1.5 % relative to the final value
Control time: approx. 25 sec. for the entire positioning range
Finish: RAL 5015/7035
Cooling: AN

Your contact: +49 - 212 8804-0 • info@reo.de

REOLAB 320

REO three-phase AC - High voltage supply galvanically isolated from mains

Wiring diagram

Your contact: +49 - 212 8804-0 • info@reo.de

REOLAB 320

REO three-phase AC - High voltage supply galvanically isolated from mains

Dimension drawing