Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

CNW 101

Single-phase mains filters (2 lines, single-stage)

CNW 101

Unique Selling Point


  • compact construction
  • easy installation
  • touch-proof if used with insulated spade connectors
  • good damping performance at a low leakage current
  • also available as a medical version or with a lower leakage current
  • optional with overvoltage protection
  • UL approval for the complete model range - E217177 (not for N- and MED-versions)

 

Description


Applications: Switch-mode power supplies for industrial electronics, telecommunications, data systems engineering and DC applications. 

  • Conforming to: VDE 0565-3 / IEC 950 / UL 1283
  • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s
  • Overload: 1,5 x I 1 min/h
  • Climatic category: DIN IEC 68 Teil 1 25/085/21

Technical Data


  • Nominal Voltage : 250 V
  • Rated current : 3 - 20 A

Recommended filter for suppressing interference according to EN 55011, Class A and EN 61800-3, category C2.

Low-cost filter with small dimensions and good damping performance for the direct installation in a case on the interference source. The filter is also as a version with low leakage current as well as special medical version (no Y capacitors) available. 

Optionally, the filter can be delivered with overvoltage protection. The connection with insulated spade connections enables a fast and touch-proof assembly. Also other versions with different connections (like clamp or braid) are possible. 

 

Circuit example

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 101

Single-phase mains filters (2 lines, single-stage)

 Technical data

Type

Rated voltage

[V]

Rated current

[A]

Leakage current

[mA]

Cx

[µF]

Cy

[nF]

L

[mH]

R

[kOhm]

CNW 101/3

250

3

<3,5

0,94

20

3,3

560

CNW 101/6

6

<3,5

0,94

20

1,8

560

CNW 101/10

10

<3,5

0,94

20

1,8

560

CNW 101/16

16

<3,5

0,94

20

1,2

560

CNW 101/20

20

<3,5

0,94

20

1,0

560

CNW 101/3/N

3

<0,5

0,94

4,4

3,3

560

CNW 101/6/N

6

<0,5

0,94

4,4

1,8

560

CNW 101/10/N

10

<0,5

0,94

4,4

1,8

560

CNW 101/16/N

16

<0,5

0,94

4,4

1,2

560

CNW 101/20/N

20

<0,5

0,94

4,4

1,0

560

CNW 101/3/MED

3

<0,005

0,94

-

3,3

560

CNW 101/6/ MED

6

<0,005

0,94

-

1,8

560

CNW 101/10/ MED

10

<0,005

0,94

-

1,8

560

CNW 101/16/ MED

16

<0,005

0,94

-

1,2

560

CNW 101/20/ MED

20

<0,005

0,94

-

1,0

560

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 101

Single-phase mains filters (2 lines, single-stage)

Dimensions

 

Type

Connection

PE-Connection

Dimensions

B

mm

D

mm

H

mm

L 1

mm

L 2

mm

L 3

mm

CNW 101/3

1

1

45

4,2

30

70

60

52

CNW 101/6

1

1

45

4,2

30

70

60

52

CNW 101/10

1

1

50

5,3

30

85

75

65

CNW 101/16

1

1

50

5,3

30

85

75

65

CNW 101/20

1

1

50

5,3

30

85

75

65

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 101

Single-phase mains filters (2 lines, single-stage)

Insertion loss