Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

CNW 102

Single-phase mains filters (2 lines, two-stages)

CNW 102

Unique Selling Point


  • compact construction
  • easy installation
  • touch-proof if used with insulated spade connectors
  • very good damping performance at a low leakage current
  • also as a medical version or with a lower leakage current available
  • optional with overvoltage protection
  • UL approval for the complete model range - E217177 (except N- and MED-versions)

 

Description


Applications: Switch-mode power supplies for industrial electronics, frequency converters for motor drives, power supply units, medical and telecommunication applications, DC applications

  • Conforming to: VDE 0565-3 / IEC 950 / UL 1283
  • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s
  • Overload: 1,5 x I 1 min/h
  • Climatic category: DIN IEC 68 Teil 1 25/085/21

Technical Data


  • Nominal Voltage : 250 V
  • Rated current : 3 - 20 A

Recommended filter for suppressing interference according to EN 55011, Class A and EN 61800-3, category C2. Low-cost filter with small dimensions and very good damping performance for the direct installation in a case on the interference source.

The filter is also as a version with low leakage current as well as special medical version (no Y capacitors) available.Optionally, the filter can be delivered with overvoltage protection.

The connection with insulated spade connections enables a fast assembly. Also other versions with different connections (like clamp or braid) are possible.

 

Circuit example 

 

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 102

Single-phase mains filters (2 lines, two-stages)

 Technical data

Type

Rated voltage

[V]

Rated current

[A]

Leakage current

[mA]

Cx

[µF]

Cy

[nF]

L

[mH]

R

[kOhm]

CNW 102/3

250

3

<3,5

0,94

20

13,6

560

CNW 102/6

6

<3,5

0,94

20

7,8

560

CNW 102/10

10

<3,5

0,94

20

3,6

560

CNW 102/16

16

<3,5

0,94

20

2,4

560

CNW 102/20

20

<3,5

0,94

20

2,0

560

CNW 102/3/N

3

<0,5

0,94

4,4

13,6

560

CNW 102/6/N

6

<0,5

0,94

4,4

7,8

560

CNW 102/10/N

10

<0,5

0,94

4,4

3,6

560

CNW 102/16/N

16

<0,5

0,94

4,4

2,4

560

CNW 102/20/N

20

<0,5

0,94

4,4

2,0

560

CNW 102/3/MED

3

<0,005

0,94

-

13,6

560

CNW 102/6/ MED

6

<0,005

0,94

-

7,8

560

CNW 102/10/ MED

10

<0,005

0,94

-

3,6

560

CNW 102/16/ MED

16

<0,005

0,94

-

2,4

560

CNW 102/20/ MED

20

<0,005

0,94

-

2,0

560

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 102

Single-phase mains filters (2 lines, two-stages)

Dimensions

 

Type

Connection

PE-Connection

Dimensions

B

mm

D

mm

H

mm

L 1

mm

L 2

mm

L 3

mm

CNW 102/3

6,3x0,8mm flat plug

6,3x0,8mm flat plug

50

5,3

40

87

75

65

CNW 102/6

6,3x0,8mm flat plug

6,3x0,8mm flat plug

50

5,3

40

87

75

65

CNW 102/10

6,3x0,8mm flat plug

6,3x0,8mm flat plug

50

5,3

40

87

75

65

CNW 102/16

6,3x0,8mm flat plug

6,3x0,8mm flat plug

53

5,3

40

110

100

90

CNW 102/20

6,3x0,8mm Flachstecker

6,3x0,8mm Flachstecker

53

5,3

40

110

100

90

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 102

Single-phase mains filters (2 lines, two-stages)

Insertion loss