Download PDF
Your contact: +49 - 212 8804-0 • info@reo.de

CNW 116

Single-phase mains filters (2 lines, single-stage)

CNW 116

Unique Selling Point


  • compact construction
  • easy installation
  • touch-proof terminals
  • low temperature rise
  • dimensions compatible to those of other manufacterers
  • UL approval for the CNW 116/12 - E217177 

Description


Applications: Inverter applications, switch-mode power supplies for industrial electronics, telecommunications, data systems engineering and medical equipment

  • Conforming to: VDE 0565-3 / IEC 950 / UL 1283
  • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s
  • Overload: 1,5 x I 1 min/h
  • Climatic category: DIN IEC 68 Teil 1 25/085/21

Technical Data


  • Nominal Voltage : 250 V
  • Rated current : 8 - 63 A

Recommended filter for suppressing interference according to EN 55011, Class A and EN 61800-3, category C2. Compact filter with touch-proof terminals for inverter and industrial applications.

The filter is also as a version with low leakage current available.  

 

Circuit example

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 116

Single-phase mains filters (2 lines, single-stage)

Technical data

Type

Rated voltage

[V]

Rated current

[A]

Leakage current

[mA]

Cx

[µF]

Cy

[nF]

L

[mH]

R

[kOhm]

CNW 116/8

250

8

<3,5

3

115

10

560

CNW 116/12

12

<3,5

3

115

7,5

560

CNW 116/20

20

<3,5

3

115

3,2

560

CNW 116/33

33

<3,5

3

115

1,3

560

CNW 116/40

40

<3,5

3

115

1,3

560

CNW 116/63

63

<3,5

4,4

40

1,0

560

 

Frequency 50/60 Hz

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 116

Single-phase mains filters (2 lines, single-stage)

Dimensions

 

 

Type

Dimensions

Connection

PE-Connection

B1

[mm]

B2

[mm]

B3

[mm]

H1

[mm]

L1

[mm]

L2

[mm]

L3

[mm]

CNW 116/8

105

95

84,5

57

120

100

51

Terminals 4 mm2

Earthing bolt (M5)

CNW 116/12

105

95

84,5

57

120

100

51

Terminals 4 mm2

Earthing bolt (M5)

CNW 116/20

105

95

84,5

57

120

100

51

Terminals 4 mm2

Earthing bolt (M6)

CNW 116/33

105

95

84,5

57

120

100

51

Terminals 6 mm2

Earthing bolt (M6)

CNW 116/40

105

95

84,5

57

120

100

51

Terminals 6 mm2

Earthing bolt (M6)

CNW 116/63

98

78

70

70

180

150

90

Terminals 10 mm2

Earthing bolt (M6)

Your contact: +49 - 212 8804-0 • info@reo.de

CNW 116

Single-phase mains filters (2 lines, single-stage)

Insertion loss  

Per CISPR 17

Blue graph 50Ω/50Ω asym.           Red graph 50Ω/50Ω sym.