Train chokes

Train chokes

Train chokes for standardized safety

REO has set itself the task of helping to ensure that trains are safer today and in the future. With special chokes for rail technology, we ensure that a safe operation is possible and EMC problems are eliminated at source.

Thus, voltage changes, short circuits and other phenomena that occur in dealing with electricity, does not endanger crew members and passengers. Compliance with international standards such as EN 45545 or EN 60310, the use of the latest technologies and decades of experience make REO a strong partner.

  • CNW MD 903

    Three-phase mains choke with indirect cooling 4% Uk

    CNW MD 903
    • Nominal Voltage: 400 V
    • Rated current: 200 - 1200 A
    • Inductance: 0,024 - 0,147 mH

    Power Noise Reduction - save up to 20% energy costs.


    A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By efficiently cooling the power losses is dissipated up to 80% in cooling and reduces heating of switching cabinets. The targeted derivative of the losses via the cooling circuit prevents that losses are discharged into the environment. By using water cooling the temperatures in the components can be reduced greatly - this means less stress for the insulation materials and a longer service life.


    Starting currents and current peaks are reduced up to 60%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated current: U ≤ 3 x 400 V

    • Short circuit:: Uk 4% (400VAC/50Hz, INenn)

    • Frequency:  50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Insulation class: T40/F

    • Protection rating: IP00

    • Climatic categorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h

    • Cooling medium: Water/Glycol (70/30 %)

    • Max. Coolant outlet temperature: 50 ° C

    • Flow rate: min. 3,6 l/min.

    • Pressure drop: <0,5 bar




    Typical applications



    • Drive systems for motor drives:


      • Mechanical engineering

      • Elevators / escalators

      • Pipes

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies

    • Wind turbines

  • LD 100

    Air choke with copper/layer winding

    LD 100
    • Rated current: 50 - 1000 A
    • Inductance: 0,2 - 8 mH

    Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.


    With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.



    • Frequency of the current: DC und AC

    • Tolerances: + 10 / - 10 %, + 5 / - 5 %

    • Taps: By default, no taps (available on request)

    • Insulation: F or H

    • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF

    • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs

    • Mounting: Suspended, vertical or horizontal

    • Mechanical strength, mechanical simulation (FEM): EN 12663

    • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B



    REO Mix & Match principle 


    With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.


    REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.


    Optional



    • Layer winding/Disc winding

    • Aluminium, Copper or aluminium+copper

    • Protections: Paint coating, protective coating, housing or REO Xtreme

    • Cooling fan/unit

    • Sensors: Switch NO / NC, PT100, NTC, PTC



  • LD 110

    Air choke with aluminium/layer winding

    LD 110
    • Rated current: 50 - 1000 A
    • Inductance: 0,2 - 8 mH

    Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.


    With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.



    • Frequency of the current: DC und AC

    • Tolerances: + 10 / - 10 %, + 5 / - 5 %

    • Taps: By default, no taps (available on request)

    • Insulation: F or H

    • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF

    • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs

    • Mounting: Suspended, vertical or horizontal

    • Mechanical strength, mechanical simulation (FEM): EN 12663

    • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B



    REO Mix & Match principle 


    With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.


    REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.


    Optional



    • Layer winding/Disc winding

    • Aluminium, Copper or aluminium+copper

    • Protections: Paint coating, protective coating, housing or REO Xtreme

    • Cooling fan/unit

    • Sensors: Switch NO / NC, PT100, NTC, PTC



  • LD 120

    Air choke with aluminium-copper/layer winding

    LD 120
    • Rated current: 200 - 1000 A
    • Inductance: 0,2 - 8 mH

    Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.


    With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.



    • Frequency of the current: DC und AC

    • Tolerances: + 10 / - 10 %, + 5 / - 5 %

    • Taps: By default, no taps (available on request)

    • Insulation: F or H

    • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF

    • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs

    • Mounting: Suspended, vertical or horizontal

    • Mechanical strength, mechanical simulation (FEM): EN 12663

    • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B



    REO Mix & Match principle 


    With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.


    REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.


    Optional



    • Layer winding/Disc winding

    • Aluminium, Copper or aluminium+copper

    • Protections: Paint coating, protective coating, housing or REO Xtreme

    • Cooling fan/unit

    • Sensors: Switch NO / NC, PT100, NTC, PTC



  • LD 200

    Air choke with copper/disc winding

    LD 200
    • Rated current: 100 - 700 A
    • Inductance: 1 - 8 mH

    Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.


    With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.



    • Frequency of the current: DC und AC

    • Tolerances: + 10 / - 10 %, + 5 / - 5 %

    • Taps: By default, no taps (available on request)

    • Insulation: F or H

    • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF

    • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs

    • Mounting: Suspended, vertical or horizontal

    • Mechanical strength, mechanical simulation (FEM): EN 12663

    • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B



    REO Mix & Match principle 


    With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.


    REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.


    Optional



    • Layer winding/Disc winding

    • Aluminium, Copper or aluminium+copper

    • Protections: Paint coating, protective coating, housing or REO Xtreme

    • Cooling fan/unit

    • Sensors: Switch NO / NC, PT100, NTC, PTC



  • LD 210

    Air choke with aluminium/disc winding

    LD 210
    • Rated current: 100 - 700 A
    • Inductance: 1 - 8 mH

    Air chokes are particularly used where high inductive linearity is required. Due to their relatively simple mechanical structure, they are not only compact, but also very robust.


    With our expertise, the REO air chokes perform to the required standard, even in the most arduous conditions.



    • Frequency of the current: DC und AC

    • Tolerances: + 10 / - 10 %, + 5 / - 5 %

    • Taps: By default, no taps (available on request)

    • Insulation: F or H

    • Cooling method and cooling liquid according to IEC 60310: AN, AF or WF

    • Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs

    • Mounting: Suspended, vertical or horizontal

    • Mechanical strength, mechanical simulation (FEM): EN 12663

    • Shock - and vibration stress: IEC 61373 Kat. 1 Kl. B



    REO Mix & Match principle 


    With REO Mix & Match you can choose from a wide range of of options - combine the various options in order to always get the best product for your application.


    REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution.


    Optional



    • Layer winding/Disc winding

    • Aluminium, Copper or aluminium+copper

    • Protections: Paint coating, protective coating, housing or REO Xtreme

    • Cooling fan/unit

    • Sensors: Switch NO / NC, PT100, NTC, PTC



  1. Page:
  2. 1
  3. 2

Downloads

  • Download
    Transportation Converter Solutions
    pdf

    Transportation Converter Solutions

    Efficient components from REO
    Download
  • Download
    Air chokes Product catalogue
    pdf

    Air chokes Product catalogue

    Product catalogue REO air chokes
    Download
  • Download
    Components for railway applications catalogue
    pdf

    Components for railway applications catalogue

    Product catalogue: REO components for railway applications
    Download
  • Download
    Chokes overview
    pdf

    Chokes overview

    The product range at a glanee
    Download
  • Download
    Liquid-cooled components
    pdf

    Liquid-cooled components

    Liquid-cooled components The product range at a glance
    Download
  • Download
    REO chokes with high protection ratings
    pdf

    REO chokes with high protection ratings

    REO chokes with high protection ratings Fully encapsulated REO chokes
    Download