Mains chokes

Mains chokes

Reduce noise and save money with mains chokes

A line reactor relieved the supply network by compensating the harmonics reactive power, The harmonics are greatly reduced .

The conditional by the operating principle of rectification very high current peak is attenuated by the inductance by more than 60 %.

 Why the additional installation of a line reactor ?

- Attenuation of the very high current peaks up to 40%

- Minimizing the deformation of the sinusoidal mains voltage

- Discharge of the supply system by reactive power compensation

- Limitation of mains disturbances like voltage sags and spikes



  • CNW M 901

    Fully encapsulated single-phase mains choke 4% Uk

    CNW M 901
    • Nominal Voltage: 230 V
    • Rated current: 2 - 50 A
    • Inductance: 0,57 - 14,5 mH

    The mains chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.


    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced much. By using a mains choke the inverter electronics and DC-capacitors will be protected.


    Starting currents and current peaks are reduced up to 60%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated voltage: U ≤ 250 V 

    • Short circuit: Uk 4% (230VAC/50Hz, INenn)

    • Frequency: 50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-PE 2500 V, DC 1s

    • Insulation class: T40/F

    • Protection ratings: IP00 up to IP66

    • Klimakategorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h

    • Design: mounted on foot print


     


    Typical Applications



    • Drive systems for motor drives:


      • Mechanical engineeringPumpen

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies



  • CNW M 903

    Fully encapsulated three-phase mains choke 4% Uk

    CNW M 903
    • Nominal Voltage: 500 V
    • Rated current: 3 - 36 A
    • Inductance: 0,81 - 9,8 mH

    The mains chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.


    Power Noise Reduction - save up to 20% energy costs. A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.


    Starting currents and current peaks are reduced up to 60%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated voltage: U ≤ 3 x 500 V 

    • Short circuit: Uk 4% (400VAC/50Hz, INenn)

    • Frequency: 50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Insulation class: T40/F

    • Protection ratings: IP00 up to IP66

    • Climatic categorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h


    • Design: mounted on footprint




     


    Typical applications



    • Drive systems for motor drives:


      • Mechanical engineering

      • Elevators / escalators

      • Pipes

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies

    • Wind turbines


     

  • CNW M 905

    Fully encapsulated three-phase mains choke 2% Uk

    CNW M 905
    • Nominal Voltage: 500 V
    • Rated current: 3 - 36 A
    • Inductance: 0,4 - 4,8 mH

    The mains chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.


    Power Noise Reduction - save up to 15% energy costs. A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.


    Starting currents and current peaks are reduced up to 30%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated voltage: U ≤ 3 x 500 V

    • Short circuit: Uk 2% (400VAC/50Hz, INenn)

    • Frequency:  50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Insulation class: T40/F

    • Protection rating: IP00 up to IP66

    • Climatic categorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h

    • Design: mounted on footprint


     


    Typical applications



    • Drive systems for motor drives:


      • Mechanical engineering

      • Elevators / escalators

      • Pipes

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies

    • Wind turbines


     

  • CNW M 906

    Fully encapsulated three-phase mains choke 1% Uk

    CNW M 906
    • Nominal Voltage: 500 V
    • Rated current: 3 - 36 A
    • Inductance: 0,2 - 2,44 mH

    The mains chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.


    Power Noise Reduction - save up to 10% energy costs. A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.


    Starting currents and current peaks are reduced up to 15%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated voltage: U ≤ 3 x 500 V

    • Short circuit: Uk 1% (400VAC/50Hz, INenn)

    • Frequency:  50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Insulation class: T40/F

    • Protection rating: IP00 up to IP66

    • Climatic categorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h

    • Design: mounted on footprint


     


    Typical applications



    • Drive systems for motor drives:


      • Mechanical engineering

      • Elevators / escalators

      • Pipes

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies

    • Wind turbines


     

  • CNW MC 903

    Fully encapsulated three-phase mains choke 4% Uk

    CNW MC 903
    • Nominal Voltage: 500 V
    • Rated current: 6 - 70 A
    • Inductance: 0,42 - 4,88 mH

    Mains choke with water cooling for use on the mains side of the converter to reduce harmonics and commutation losses. By using water cooling, higher performances and a smaller design of the device can be implemented. Modular design for IP 00, IP 20 and IP 64/66 possible.



    • Conforming to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Rated voltage: U = 3 x 500 V

    • Insulation material class: T40/B

    • Protection: Variants of IP00 up to IP66 possible

    • Climartic category: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h



  • CNW MD 903

    Three-phase mains choke with indirect cooling 4% Uk

    CNW MD 903
    • Nominal Voltage: 400 V
    • Rated current: 200 - 1200 A
    • Inductance: 0,024 - 0,147 mH

    Power Noise Reduction - save up to 20% energy costs.


    A mains choke relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By efficiently cooling the power losses is dissipated up to 80% in cooling and reduces heating of switching cabinets. The targeted derivative of the losses via the cooling circuit prevents that losses are discharged into the environment. By using water cooling the temperatures in the components can be reduced greatly - this means less stress for the insulation materials and a longer service life.


    Starting currents and current peaks are reduced up to 60%. Mains chokes helps to comply with international power quality standards IEEE 519 or EN 61000-3-2.



    • Rated current: U ≤ 3 x 400 V

    • Short circuit:: Uk 4% (400VAC/50Hz, INenn)

    • Frequency:  50/60 Hz

    • According to: EN 60289 / EN 61558

    • Test voltage: L-L 2500 V, DC 1min; L-PE 2500 V, DC 1min

    • Insulation class: T40/F

    • Protection rating: IP00

    • Climatic categorie: DIN IEC 60068-1

    • Overload: 1,5 x INenn 1 min / h

    • Cooling medium: Water/Glycol (70/30 %)

    • Max. Coolant outlet temperature: 50 ° C

    • Flow rate: min. 3,6 l/min.

    • Pressure drop: <0,5 bar




    Typical applications



    • Drive systems for motor drives:


      • Mechanical engineering

      • Elevators / escalators

      • Pipes

      • Conveyor technology

      • Ventilation and air conditioning

      • Robotics

      • Automation technology


    • Power supplies

    • Wind turbines

  1. Page:
  2. 1
  3. 2
  4. 3

Downloads

  • Download
    Protection Ratings
    pdf

    Protection Ratings

    Discover our brochure about high protection ratings!
    Download
  • Download
    Energy saving with mains chokes and harmonic filters
    pdf

    Energy saving with mains chokes and harmonic filters

    Save up to 30% energy!
    Download
  • Download
    REO energy savers
    pdf

    REO energy savers

    Save money with less reactive power
    Download
  • Download
    Liquid cooled systems catalog
    pdf

    Liquid cooled systems catalog

    Product catalog for liquid cooled systems
    Download
  • Download
    Components for wind power generation Catalouge
    pdf

    Components for wind power generation Catalouge

    REO components for wind power generation Safe application for onshore and offshore installations
    Download
  • Download
    Liquid-cooled components
    pdf

    Liquid-cooled components

    Liquid-cooled components The product range at a glance
    Download
  • Download
    REO chokes with high protection ratings
    pdf

    REO chokes with high protection ratings

    REO chokes with high protection ratings Fully encapsulated REO chokes
    Download
  • Download
    REO Filter combination CNW 985
    pdf

    REO Filter combination CNW 985

    for a smooth current
    Download
  • Download
    CNW 953
    pdf

    CNW 953

    Reduce network disturbances - saving energy costs
    Download
  • Download
    REO Regenerative Line Reactors CNW 953
    pdf

    REO Regenerative Line Reactors CNW 953

    REO Regenerative Line Reactors CNW 953 for the use with regenerative converters
    Download