Passive Current transformers

Low space requirements combined with outstanding performance

REO current transformers distinguish themselves primarily due to their low space requirements, excellent linearity, short response times and their low iron und hysteresis losses.

The current transformer series are available in a range up to 150 kHz and, as a result of the testing that has previously been performed and is carried out in the manufacturing process, whether that is vacuum casting, partial discharge measurement or high-voltage testing, achieve a high level of reliability and are perfectly adapted to the respective place of use.

  • Series IB

    Current transformers for printed-circuit boards

     Series IB
    • Primary rated current: 0 - 40 A

    REO current transformers series IB are suitable for mounting on printed-circuit boards in the electric range of modern drive engineering for control purposes and measurement value logging. All safety regulations as for example double insulation are obtained.


    Application area




    •  Control purposes and measurement value logging







  • Series IN-I

    Pulsed current transformer

     Series IN-I
    • Primary rated current: 50 - 200 A

    Because of the materials selected, REO pulsed current transformers in the IN-I series monitor current with high precision and in the appropriate transformation ratio - which makes them particularly suitable for power measurements, current monitoring and analysis, and for use in solar inverters. They are ideal for use in active filters, as they can be designed to measure current surges.


    The primary current is measured in a conductor fed through the closed toroidal core.


    The magnetic field generated by the flow of current through the conductor is detected by the toroidal core, which, in accordance with the transformation ratio of the secondary winding, generates a smaller current for measurement purposes. By this means, a heavy current to be measured is reduced to a substantially smaller current and is in addition isolated from the primary circuit by safe electrical isolation.



    • According to: EN60044-1

    • Primary rated current: 50 - 200 A

    • Frequency: 50 - 50.000 Hz



    Application area




    • Metrology and testing techniques




  • Series IE

    Bushing-type current transformers (PIN version)

    Series IE
    • Primary rated current: 1 - 50 A

    In the case of bushing-type current trans­formers, the customer’s primary wire is pushed through the current transformer opening in the housing. The push-through opening depends on the size of the primary current.


    Wound primary type current transformers have a primary winding and a secondary winding. Both windings are applied on the closed toroidal core and are isolated from each other by insulation. This principle applies mainly where primary currents are small. Low-voltage current transformers for the proportional transformation of large currents to directly measurable smaller current values.



    • According to: EN 60044-1

    • Primary rated current: 1 - 50 A

    • Frequency range: 50 - 400 Hz



    Applications



    • Industry

    • Renewable energy sources

    • Railway engineering

    • Energy, automation and building technology




  • Series IE

    Bushing-type current transformers (Strands/clamps)

    Series IE
    • Primary rated current: 50 - 3000 A

    In the case of bushing-type current trans­formers, the customer’s primary wire is pushed through the current transformer opening in the housing. The push-through opening depends on the size of the primary current.


    Wound primary type current transformers have a primary winding and a secondary winding. Both windings are applied on the closed toroidal core and are isolated from each other by insulation. This principle applies mainly where primary currents are small. Low-voltage current transformers for the proportional transformation of large currents to directly measurable smaller current values.



    • According to: EN 60044-1

    • Primary rated current: 50 - 3000 A

    • Frequency range: 50 - 400 Hz



    Applications



    • Industry

    • Renewable energy sources

    • Railway engineering

    • Energy, automation and building technology




  • Series IE modular

    closed-loop current transformers

    Series IE modular
    • Primary rated current: 500 - 2500 A
    • Umgebungstemperatur: -25... +70 °C
    • Frequency range: 50... -400 Hz

    In the case of bushing-type current transformers, the customer’s primary wire is pushed
    through the current transformer opening in the housing. The push-through opening depends
    on the size of the primary current.
    Wound primary type current transformers have a primary winding and a secondary winding.
    Both windings are applied on the closed toroidal core and are isolated from each other by
    insulation. This principle applies mainly where primary currents are small. Low-voltage current
    transformers for the proportional transformation of large currents to directly measurable
    smaller current values.

    According to: 61869-2
    Primary rated current: 500, 1000, 2500 A
    Frequency range: 50 - 400 Hz

    Applications:



    • Industry

    • Renewable energy sources

    • Railway engineering

    • Energy, automation and building technology

  • Series IN

    Instrument transformers (Strands/clamps)

    Series IN
    • Primary rated current: 50 - 1000 A

    The growing development and spread of electronic devices with high working frequencies requires the use of current transformers with an extended frequency range.


    This demand can be met with specially selected materials in conjunction with optimized design.



    • According to: EN 60044-1

    • Primary rated current: 50 - 1.000 A

    • Frequency range: 50 - 50.000 Hz



    Application area



    • Industry

    • Renewable energy sources

    • Railway engineering

    • Metrology and testing techniques

    • Energy, automation and building technology



  1. Page:
  2. 1
  3. 2