EMC-Filter

No line-conducted interferences due to the EMC filter

EMC filters are used for suppressing line-conducted interferences.

The spreading is prevented by a maximum level of impedance mismatch. The filtering effect extends in both directions. This means that both the interference from the consumer to the network and the interference from the network to the consumer are suppressed.

  • CNW 101

    Single-phase mains filters (2 lines, single-stage)

    CNW 101
    • Nominal Voltage: 250 V
    • Rated current: 3 - 20 A

    Applications: Switch-mode power supplies for industrial electronics, telecommunications, data systems engineering and DC applications. 



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 102

    Single-phase mains filters (2 lines, two-stages)

    CNW 102
    • Nominal Voltage: 250 V
    • Rated current: 3 - 20 A

    Applications: Switch-mode power supplies for industrial electronics, frequency converters for motor drives, power supply units, medical and telecommunication applications, DC applications



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 103

    Three-phase mains filters (3 lines, single-stage)

    CNW 103
    • Nominal Voltage: 440 V
    • Rated current: 3 - 150 A
    Applications: Frequency converters for motor drives (e.g. lifts, materials handling, pumps, ventilation and air-conditioning systems, industrial applications, wind power installations and power supply units
    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283
    • Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s
    • Overload: 1,5 x I 1 min/h
    • Climatic category: DIN IEC 68 Teil 1 25/085/21
  • CNW 104

    Three-phase mains filters (3 lines, two stages)

    CNW 104
    • Nominal Voltage: 480 V
    • Rated current: 3 - 150 A

    Applications: Frequency converters for motor drives e.g. lifts, materials handling, pumps, ventilation and air-conditioning systems, industrial and household applications, wind power installations and power supply units



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 107.3/480

    High-current mains filters (3 lines)

    CNW 107.3/480
    • Nominal Voltage: 480 V
    • Rated current: 280 - 3000 A

    Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 107.3/690

    High-current mains filters (3 lines)

    CNW 107.3/690
    • Nominal Voltage: 690 V
    • Rated current: 280 - 3000 A

    Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  1. Page:
  2. 1
  3. 2
  4. 3
  5. 4

Downloads

  • Download
    PowerQuality Solutions
    pdf

    PowerQuality Solutions

    Powerful solutions for trouble-free power
    Download
  • Download
    Protection Ratings
    pdf

    Protection Ratings

    Discover our brochure about high protection ratings!
    Download
  • Download
    EMC-Filter Product catalogue
    pdf

    EMC-Filter Product catalogue

    Product catalogue
    Download
  • Download
    Components for wind power generation Catalouge
    pdf

    Components for wind power generation Catalouge

    REO components for wind power generation Safe application for onshore and offshore installations
    Download
  • Download
    High ingress protection ratings make a difference
    pdf

    High ingress protection ratings make a difference

    REO EMC-Filter with IP66
    Download
  • Download
    EMC-Filters overview
    pdf

    EMC-Filters overview

    EMC-Filters The product Prraondguec ta tc aat aglloagnucee
    Download
  • Download
    PLC- and circuit filter
    pdf

    PLC- and circuit filter

    for use with Powerline Communication (PLC) faults
    Download
  • Download
    Components for efficient charging systems and hybrid/electric drives
    pdf

    Components for efficient charging systems and hybrid/electric drives

    around e-mobility
    Download
  • Download
    REOWAVE®passive Plus
    pdf

    REOWAVE®passive Plus

    The new generation of harmonic filters
    Download