de

EMC-Filter

No line-conducted interferences due to the EMC filter

EMC filters are used for suppressing line-conducted interferences.

The spreading is prevented by a maximum level of impedance mismatch. The filtering effect extends in both directions. This means that both the interference from the consumer to the network and the interference from the network to the consumer are suppressed.

  • CNW 101

    Single-phase mains filters (2 lines, single-stage)

    CNW 101
    • Nominal Voltage: 250 V
    • Rated current: 3 - 20 A

    Applications: Switch-mode power supplies for industrial electronics, telecommunications, data systems engineering and DC applications. 



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 107.3/480

    High-current mains filters (3 lines)

    CNW 107.3/480
    • Nominal Voltage: 480 V
    • Rated current: 280 - 3000 A

    Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 107.3/690

    High-current mains filters (3 lines)

    CNW 107.3/690
    • Nominal Voltage: 690 V
    • Rated current: 280 - 3000 A

    Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 114/690

    Three-phase mains filters (3 lines)

    CNW 114/690
    • Nominal Voltage: 690 V
    • Rated current: 80 - 1200 A

    Applications: Frequency converters for motor drives, wind power installations and power supply units



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 114/500

    Three-phase mains filters (3 lines)

    CNW 114/500
    • Nominal Voltage: 500 V
    • Rated current: 80 - 1200 A

    Applications: Frequency converters for motor drives, wind power installations and power supply units



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21

  • CNW 208

    Three-phase mains filter (3 lines)

    CNW 208
    • Nominal Voltage: 480 V
    • Rated current: 7 - 180 A

    Applications: Frequency converters for motor drives, wind power installations and power supply units.



    • Conforming to: VDE 0565-3 / IEC 950 / UL 1283

    • Test voltage: L-L 2100 V,DC 1s, L-PE 2700 V,DC 1s

    • Overload: 1,5 x I 1 min/h

    • Climatic category: DIN IEC 68 Teil 1 25/085/21